Tendon Primary Load Case

Question:

I need some assistance with regards to the 'Tendon Primary' load case. I am currently doing a PSC Check on stresses for cross section at service loads. Does it have to be included on the Serviceability load cases?



Answer:
Hi,

Yes, both tendon primary and tendon secondary should be included in the load combination for serviceability.

Regards,
DK Lee
Creation date: 6/27/2018 9:07 PM (dklee@midasit.com)      Updated: 6/28/2018 6:38 AM (dklee@midasit.com)
Files   
1530118022377812063993.jpg
resend
1530118102062138311258.jpg
resend
15301181174021641096218.jpg
resend
mnl-133-97_ch9_3.pdf
resend