Answer:

Actually, the stiffness of the section is high thus causing numerical instability in the stiffness matrix. Thus, it is advised to use either a rigid link in place of a stiff member or provide a stiffness value of 10 m4. This will solve the issue. The model has been attached for review.


Creation date: 5/31/2021 4:18 PM      Updated: 5/30/2023 4:28 AM
Files   
MBR-RSI-Option 3-TPc-P12-North Plank.mcb
7 MB
MBR-RSI-Option 3-TPc-P12-North Plank_modified.mcb
7 MB
MBR-RSI-Option 3-TPc-P12-North Plank-Just Plank2.mcb
768 KB
MBR-RSI-Option 3-TPc-P12-North Plank-North Plank Removed2.mcb
7 MB