Prestress load during stage

Question:

Hi,

Pretension load on embedded truss looks not working correctly during construction stage, please look attached file and let me know.


Answer:

Hi,

The reason for zero displacement is that you activated tendon at stage 1 and activated prestress at stage 2. In order to apply prestress properly, the tendon and prestress should activate at the same stage. 

Regards,
DK Lee
Technical Manager