Prestress load during stage
Question:

Answer:
Hi,
Hi,
Pretension load on embedded truss looks not working correctly during construction stage, please look attached file and let me know.
Answer:
Hi,
The reason for zero displacement is that you activated tendon at stage 1 and activated prestress at stage 2. In order to apply prestress properly, the tendon and prestress should activate at the same stage.