Prestress load during stage

Question:

Hi,

Pretension load on embedded truss looks not working correctly during construction stage, please look attached file and let me know.


Answer:

Hi,

The reason for zero displacement is that you activated tendon at stage 1 and activated prestress at stage 2. In order to apply prestress properly, the tendon and prestress should activate at the same stage. 

Regards,
DK Lee
Technical Manager

Click here to give FEEDBACK