The error ‘Section Dimensions has(have) been incorrectly entered’ appears when trying to import sections into Midas Civil as 'PSC' section. How can I solve this error?
Answer:
To import a PSC section, the design parameter dimensions have to be entered as shown below.
These dimensions are to be used for design. The dimensions are used for calculating the shear strength. If 0 is inputted in T2, then the program automatically recognizes the section as a Tee section and uses BT as web thickness.
Once this is done, the error is not obtained.
Following manual can be referred to input "Parameter for Design" for different type of sections:
Go to PSC tab>Value Type PSC Section
Files | ||
---|---|---|
DataImage26.png 55 KB |
||
S6-8.mcb 194 KB |
||
T-BEAM MID.sec 549 b |
||
T-BEAM SUPPORT.sec 455 b |
||
U20.sec 770 b |