Considering Suggested 9/12/2019 by Dylan Danks

1

votes

Load Rate Substructure

I was trying to do a load rating on a delta frame bridge and the program would only rate the superstructure. For most cases this is all that is needed. However, since the delta is a frame system meaning the superstructure and substructure are joined, the substructure had to be rated because it could control over the superstructure. I did the substructure rating by hand, but it would be nice if the program could handle rating it. 

avatar
Angela Kim
Hi Dylan, can you please share your model file and drawing? If you do not wish to post it here, please kindly send it to angelakim@midasoft.com. Thanks!
9/12/2019 6:52 PM
avatar
Angela Kim
Hi Dylan,

After the review of the model file, it looks like load rating of regular steel (non-composite section) will serve your needs, is it right?
9/12/2019 8:29 PM
avatar
Dylan Danks
Yes load rating of regular steel non-composite would serve my needs.
9/12/2019 8:37 PM

Log in to comment...