[PSC]     How to view the ultimate moment capacity of PSC girder along with the design moment?

To view the sufficiency of the Design, pictorial depiction to compare
Ultimate Moment/Shear capacity of the girder with the Design Force / Moment is possible.


After performing the PSC design of the sections, under PSC tab  PSC Result Diagram,
the section capacity can be viewed in form of values or its capacity scaled up.





As depicted in the image above, the required components and options can be chosen to view the desired results. This is a very quick way of verifying if the section is over safe or
failing at certain locations.
Creation date: 6/22/2016 7:25 PM      Updated: 9/5/2017 9:38 AM
Files   
2016_FAQ_Vol.1_image (1)[1].jpg
59 KB
Vol.1_64_How to view the ultimate moment capacity of PSC girder along with the design moment.pdf
91 KB