Design results empty

Question:

Hi all,

analysis and composite design run and complete correctly but design resuts are empty

thanks

regards



Answer:

Hi,

If you look at the 'Fatigue Load Combination Type' dialog, all load combinations are assigned as 'Fatigue Load Combination' as shown below. This is the reason for the problem.


Regards,
DK Lee
Creation date: 9/8/2019 7:10 PM (dklee@midasit.com)      Updated: 9/9/2019 4:42 AM (dklee@midasit.com)
Files   
DataImage2.png
resend
DataImage43.png
resend
DataImage86.png
resend
modello 02.mcb
resend