Limiting Slenderness Ratio

Question:

Hi,

Refer to the attached file, can I know how to change the limit of the slenderness ratio for the tension member? Although the limit of the slenderness ratio is already set at 300 for tension member. However, the analysis shows that the limit is 200 only. Can you assist me?

Thank you.

Regards,

Answer:
Hello,

Limiting Slenderness Ratio is for the design step. Default value is defined as 200 and 300 for each compression and tension. If you want to use the other value for the limiting value, just enter the value and select the element and then click the apply button with Add/Replace option.

Thank you.

Best regards,
Jihong Hwang